Skip to content

in_hot_standby

in_hot_standby shows whether hot standby is currently active. It is read-only metadata in PG14–18, not a runtime tuning control.
Note

Fact — official short description: “Shows whether hot standby is currently active.”

Identity

Type , Valuebool
Upstream pg_settings type
Context , Valueinternal
Internal/preset and not user-settable
Unit , Value
Raw unit
Range , Value
Raw limits in the last observed version
Enum values , Value
— for non-enum types
Category , ValuePreset Options
Upstream classification
Latest boot value , Valueoff
off

Lifecycle

Fact Value
First observed PG14
Present in PG14–19 Beta 3
Removed in No
Introduction commit bf8a662c9afa — Introduce a new GUC_REPORT setting “in_hot_standby”.
Commit date 2021-01-05
Discussion thread 1

Default history

Measured PG9.0–19 Beta 3 boot defaults
Versions Raw boot_val Unit Human value
PG14–19 Beta 3 off off

How it works

Shows whether hot standby is currently active. It is read-only and cannot be changed with SET or configuration-file edits.

It changes as recovery enters or leaves hot-standby operation and is intended for feature detection by SQL code.

Interpret it with hot_standby, max_standby_streaming_delay, hot_standby_feedback. Applications and operations tooling may read in_hot_standby for capability or environment detection, but cannot SET it; cross-cluster comparisons must account for build, initdb, and current-database differences.

Tuning advice

Tip

Advice. These are workload-specific starting points and must be validated with measurements.

Workload Guidance
OLTP Not tunable. Record in_hot_standby as a deployment/capability fact; if it is unexpected, fix the binary, initdb, or database-creation process rather than trying SET.
OLAP Not tunable. Use in_hot_standby to verify format, build, or resource assumptions on analytical nodes and keep every read/write candidate compatible.
Small nodes Not tunable. Preserve it in inventory and incident reports; do not custom-build or rebuild merely to change it without a demonstrated compatibility need.

Pigsty

Values use the fixed 8-vCPU, 32-GiB, 100-GiB SSD fixture and render the current Pigsty templates for PG19 Beta 3; this does not assert current Pigsty support for that historical or beta release.

Template Effective value Versus upstream boot Source expression
OLTP Unmodified
OLAP Unmodified
CRIT Unmodified
TINY Unmodified
Caution

Advice — pending human review. Fact from the current Pigsty template projection: OLTP: PG14–19 Beta 3 unmodified; OLAP: PG14–19 Beta 3 unmodified; CRIT: PG14–19 Beta 3 unmodified; TINY: PG14–19 Beta 3 unmodified. No Pigsty-specific rationale is inferred from an absent override.

Common pitfalls

  • Trying to change read-only in_hot_standby with SET or a configuration file.
  • Assuming every cluster, database, or vendor build reports the same value.
  • Ignoring the value in file-format or feature-compatibility checks.
  • Treating reported metadata as a performance target instead of an environment fact.

hot_standby · max_standby_streaming_delay · hot_standby_feedback · primary_conninfo · block_size · data_checksums