Skip to content

primary_conninfo

primary_conninfo sets the connection string to be used to connect to the sending server. It is a sighup setting present in PG12–18; the latest recorded boot default is empty.
Note

Fact — official short description: “Sets the connection string to be used to connect to the sending server.”

Identity

Type , Valuestring
Upstream pg_settings type
Context , Valuesighup
Takes effect after configuration reload
Unit , Value—
Raw unit
Range , Value—
Raw limits in the last observed version
Enum values , Value—
— for non-enum types
Category , ValueReplication / Standby Servers
Upstream classification
Latest boot value , Value""
empty string

Lifecycle

Fact Value
First observed PG12
Present in PG12–19 Beta 3
Removed in No
Introduction commit 2dedf4d9a899 — Integrate recovery.conf into postgresql.conf
Commit date 2018-11-25
Discussion thread 1

Default history

Measured PG9.0–19 Beta 3 boot defaults
Versions Raw boot_val Unit Human value
PG12–19 Beta 3 "" — empty string

How it works

Sets the connection string to be used to connect to the sending server. A configuration reload applies a new value; existing work already in flight is not retroactively changed.

The WAL receiver uses this libpq connection string to reach an upstream sender. Reloading a changed nonempty value restarts the receiver; credentials should come from a protected passfile where possible, and slot synchronization additionally requires dbname.

Monitor and change primary_conninfo together with max_wal_senders, max_replication_slots, wal_level. Validate on the relevant server role and real workload, then use its sighup context to choose session change, reload, or restart; a historical boot default is not the current effective value.

Tuning advice

Tip

Advice. These are workload-specific starting points and must be validated with measurements.

Workload Guidance
OLTP Size primary_conninfo from topology, failover roles, slot/subscription count, and reconnect headroom. Test worst-case primary latency, standby replay, and disk retention before production.
OLAP Read standbys and logical subscribers often see long queries or large transactions. Put explicit bounds on replay/apply and monitor lag, worker saturation, slot restart_lsn, and conflict cancellations.
Small nodes Configure only replication capacity that is actually used. Even a small topology needs bounded timeouts and slot lifecycle; unlimited retention is not reliability.

Pigsty

Values use the fixed 8-vCPU, 32-GiB, 100-GiB SSD fixture and render the current Pigsty templates for PG19 Beta 3; this does not assert current Pigsty support for that historical or beta release.

Template Effective value Versus upstream boot Source expression
OLTP Unmodified — —
OLAP Unmodified — —
CRIT Unmodified — —
TINY Unmodified — —
Caution

Advice — pending human review. Fact from the current Pigsty template projection: OLTP: PG12–19 Beta 3 unmodified; OLAP: PG12–19 Beta 3 unmodified; CRIT: PG12–19 Beta 3 unmodified; TINY: PG12–19 Beta 3 unmodified. No Pigsty-specific rationale is inferred from an absent override.

Common pitfalls

  • Embedding a plaintext password in broadly readable configuration or process diagnostics.
  • Omitting dbname when slot synchronization needs it.
  • Changing upstream identity without coordinating timeline and slot state.
  • Changing it on the wrong primary, standby, sender, or subscriber role.
  • Watching only configured bytes/time instead of actual lag, slot position, and worker state.

max_wal_senders · max_replication_slots · wal_level · wal_sender_timeout · max_slot_wal_keep_size · primary_slot_name

References